Feature:
1. Control system: designed for monitoring and controlling the instrument via the computer.
2. Multistage (10 ramps) programmed temperature control function.
3. Supporting real time instrument status monitoring, detection signal acquisition and PC control.
4. Column oven accommodates up to 3 chromatographic columns and supports quick heat-up and rapid cool-down with automated back-door opening.
5. Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control.
6. High sensibility and stability detector.
7. 2 independent and analog signals output.
8. Special analyzers, like RGA, NGA, PINDA, etc. according to ASTM standards.
Technical Parameters:
Model | MF-GC1120 | |
Sample Introduction System | Sample injector and evaporation chamber | |
Oven | Temp. Range | RT+7℃ ~ 400℃ |
Temp. accuracy | ± 0.02℃ | |
Cooling Time | 400℃ to 50℃ in 6 min at RT 25℃ | |
Programmed Tempe Setting | 0.1℃~40℃/min (in 1℃ increment) | |
Program Ramps | 7 ramps in total (10 ramps available with control workstation①) | |
Flame Ionization Detector (FID) | Detection Limit | ≤3*10-12g/s (C16) |
Baseline Drift | ≤6*10-13A/h | |
Thermal Conductivity Detector(TCD) (Optional) | Sensitivity | ≥5000mV.mL/mg |
Baseline Noise | ≤20µV | |
Flame Photometric Detector (FPD) (Optional) | Detection Limit | ≤8*10-13g/s(P), ≤8*10-11g/s(S) |
Baseline Drift | ≤2*10-11A/30min | |
Baseline Noise | ≤5*10-12A | |
Nitrogen-Phosphorus Detector (NPD) (Optional) | Detection Limit | ≤5*10-13g/s(P), ≤5*10-12g/s(N) |
Power Supply | AC220V ± 10%,50/60Hz | |
Optional Accessory | All kind of detectors, Inlet six-way valve, Converter, Thermal desorption device, Split inlet, Simulation and educational presentation software of chromatography, Chromatograph work station, CDP chromatographic data processor, Deoxidation tube, Glass thin-layer chromatographic column. | |
Package Size(W*D*H) mm | 830*678*850 | |
Gross Weight(kg) | 85 |
Standard Accessory
MF-GC1120-1: Capillary inlet (including blowing-up function of diaphragm and shunting
regulation with back pressure valve), make-up gas flow control, SE30 ø0.32mm*15m Capillary Column, one FID.
MF-GC1120-2: Inlet with double packed columns, one TCD.
MF-GC1120-3: Inlet with double packed columns, double FIDs
MF-GC1120-4: Inlet with single packed column, capillary inlet accessories (including blowing-up function of diaphragm and shunting regulation with back pressure valve), double FIDs.
MF-GC1120-5: Inlet with double packed columns, capillary inlet accessories (including blowing-up function of diaphragm and shunting regulation with back pressure valve), make-up gas flow control, double FIDs.
MF-GC1120-6: Inlet with double capillary inlets (including blowing-up function of diaphragm and shunting regulation with back pressure valve), double make-up gas flow control, double FIDs, packed columns inlet accessory.